"An Interdisciplinary Peer Reviewed Quaterly Published International Journal"

Design and Performance Analysis of a Planar Microstrip Filter Sensor for Non-Invasive Human Tension and Physiological Stress Detection

Authors:

Nabaa S.M. Abed

DOI:

Abstract:

Psychological stress is accompanied by autonomic changes that can modify sudomotor activity, skin hydration, and the ionic environment at the skin surface. Because tissue water content and conductivity contribute to microwave dielectric behavior, these physiological changes can perturb the electromagnetic loading experienced by a resonant sensor. This study presents a compact planar microstrip band-stop sensor operating near 2.45 GHz for non-invasive monitoring of stress-related physiological changes. The sensor uses a modified split-ring resonator (SRR) coupled to a 50-Ω microstrip line on Rogers RT/duroid 5880 (εr = 2.2, tanδ = 0.0009, h = 1.57 mm) and occupies 30 × 25 mm². HFSS simulations were performed using a three-layer skin model and the dielectric states reported in the original study. Across the modeled tissue range, ε′ increased from 38.0 to 46.5 and conductivity from 1.45 to 1.95 S/m, while the resonance shifted from 2.312 to 2.185 GHz, corresponding to a 127 MHz shift and an average sensitivity of 14.94 MHz per unit change in ε′. The unloaded-to-resting transition produced an additional 138 MHz shift and should not be confused with the tissue-state sensitivity range. Experimental measurements on 12 healthy adults used a two-port VNA and GSR as a reference physiological signal. The manuscript reports phase-level values of 2.14 ± 0.35 μS at baseline, 6.85 ± 0.92 μS during the Stroop task, and 2.80 ± 0.41 μS during recovery, with corresponding measured resonances of 2.315, 2.242, and 2.301 GHz. The previously reported R² = 0.984 is retained only as a reported experimental association because individual-level raw data are not supplied in the manuscript; confidence intervals, subject-level RMSE/MAE, and repeated-measures inference require the original paired measurements. The revised interpretation therefore treats the microwave response as a stress-related physiological proxy rather than a direct or diagnostic measure of psychological stress.

Keywords:

microwave sensor, microstrip filter, split-ring resonator, skin permittivity, electrodermal activity, physiological stress, non-invasive sensing, 2.45 GHz

Refference:

1. C. Kirschbaum, K.-M. Pirke, and D. H. Hellhammer, “The ‘Trier Social Stress Test’—a tool for investigating psychobiological stress responses in a laboratory setting,” Neuropsychobiology, vol. 28, no. 1–2, pp. 76–81, 1993. 10.1159/000119004.
2. N. F. Narvaez Linares, V. Charron, A. J. Ouimet, P. R. Labelle, and H. Plamondon, “A systematic review of the Trier Social Stress Test methodology: Issues in promoting study comparison and replicable research,” Neurobiology of Stress, vol. 13, p. 100235, 2020. 10.1016/j.ynstr.2020.100235.
3. A. Allen, E. M. Kennedy, L. Cryan, M. Dinan, and D. Clarke, “Biological and psychological markers of stress in humans: Focus on the Trier Social Stress Test,” Neuroscience & Biobehavioral Reviews, vol. 38, pp. 123–135, 2014. 10.1016/j.neubiorev.2013.11.002.
4. H. Gu, Y. Lei, Y. Yao, C. Chen, and C. Liu, “Physiological and psychological responses to acute stress: A meta-analysis of the 171 studies of Trier Social Stress Test including 8452 healthy adults,” Psychoneuroendocrinology, vol. 180, p. 107566, 2025. 10.1016/j.psyneuen.2025.107566.
5. H. F. Posada-Quintero and K. H. Chon, “Innovations in electrodermal activity data collection and signal processing: A systematic review,” Sensors, vol. 20, no. 2, p. 479, 2020. 10.3390/s20020479.
6. A. Klimek, I. Mannheim, G. Schouten, E. J. M. Wouters, and M. W. H. Peeters, “Wearables measuring electrodermal activity to assess perceived stress in care: A scoping review,” Acta Neuropsychiatrica, vol. 37, p. e19, 2023. 10.1017/neu.2023.19.
7. D. S. Bari, H. Y. Y. Aldosky, and Ø. G. Martinsen, “Electrodermal activity measurements: A review of artifacts,” Physiological Measurement, vol. 47, no. 7, 2026. 10.1088/1361-6579/ae7bae.
8. G. Vos, K. Trinh, Z. Sarnyai, and M. Rahimi Azghadi, “Generalizable machine learning for stress monitoring from wearable devices: A systematic literature review,” International Journal of Medical Informatics, vol. 173, p. 105026, 2023. 10.1016/j.ijmedinf.2023.105026.
9. A. G. Peitzsch, Y. Kong, H. F. Posada-Quintero, and K. H. Chon, “Objective assessment of acute stress disorder in female subjects using wearable measures of electrodermal activity,” in Proc. IEEE EMBC, 2024. 10.1109/EMBC53108.2024.10782849.
10. I. Royo, R. Fernández-García, and I. Gil, “Microwave resonators for wearable sensors design: A systematic review,” Sensors, vol. 23, no. 22, p. 9103, 2023. 10.3390/s23229103.
11. M. Abdolrazzaghi, V. Nayyeri, and F. Martín, “Techniques to improve the performance of planar microwave sensors: A review and recent developments,” Sensors, vol. 22, no. 18, p. 6946, 2022. 10.3390/s22186946.
12. S. Alahnomi, A. Zakaria, A. Mohd Bahar, M. A. M. Rasid, M. R. M. Hasin, and S. A. Mohd Shah, “Review of recent microwave planar resonator-based sensors: Techniques of complex permittivity extraction, applications, open challenges and future research directions,” Sensors, vol. 21, no. 7, 2021. 10.3390/s21072408.
13. A. A. al-Behadili, I. A. Mocanu, T. M. Petrescu, and T. A. Elwi, “Differential microstrip sensor for complex permittivity characterization of organic fluid mixtures,” Sensors, vol. 21, no. 23, p. 7865, 2021. 10.3390/s21237865.
14. C. Gabriel, S. Gabriel, and E. Corthout, “The dielectric properties of biological tissues: I. Literature survey,” Physics in Medicine and Biology, vol. 41, no. 11, pp. 2231–2249, 1996. 10.1088/0031-9155/41/11/001.
15. S. Gabriel, R. W. Lau, and C. Gabriel, “The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz,” Physics in Medicine and Biology, vol. 41, no. 11, pp. 2251–2269, 1996. 10.1088/0031-9155/41/11/002.
16. Y. Hu, C. Converse, M. C. Lyons, and W. H. Hsu, “Neural control of sweat secretion: A review,” British Journal of Dermatology, vol. 178, no. 6, pp. 1246–1256, 2018. 10.1111/bjd.15808.
17. S. Na, H.-J. Lee, T.-H. Park, J. Kim, Y. H. Jung, M. Cha, H.-Y. Lee, H.-J. Kim, and J.-B. Lee, “Sweat glands in action: The role of biological and environmental factors, exercise, and dermatologic conditions in sudomotor function,” Korean Journal of Physiology and Pharmacology, 2026.
18. S. Alotaibi et al., “Wearable devices for continuous monitoring of biosignals: Challenges and opportunities,” Review of Scientific Instruments, 2022. 10.1063/5.0086935.
19. E. R. M. P. et al., “Personalized stress detection using biosignals from wearables: A scoping review,” Sensors, vol. 24, no. 10, p. 3221, 2024, doi: 10.3390/s24103221.
20. H.-N. Morales-Lovera, J.-L. Olvera-Cervantes, A.-E. Perez-Ramos, A. Corona-Chavez, and C. E. Saavedra, “Microstrip sensor and methodology for the determination of complex anisotropic permittivity using perturbation techniques,” Scientific Reports, vol. 12, p. 2205, 2022. 10.1038/s41598-022-06259-8.

21. P. Chokenukul and D. Worasawate, “Simulation of a permittivity measurement system with microstrip structure at ISM frequency incorporate with lookup table,” Engineering and Technology Horizons, vol. 40, no. 4, p. 400403, 2023. 10.55003/ETH.400403.
22. A. Nella, R. W. Aldhaheri, J. B. Kamili, and A. A. Jiman, “A novel microstrip band-stop filter at 5.5 GHz for non-invasive blood glucose monitoring,” Applied Sciences, vol. 16, no. 7, p. 3197, 2026. 10.3390/app16073197.